Guide · Batteries

How to charge LiFePO4 batteries

A lithium iron phosphate battery is the most forgiving of the lithium batteries, but it does not forgive three mistakes: the wrong end-of-charge voltage, charging below freezing and a charger designed for another chemistry. Here you will find the right voltages for every configuration, the charge profile, the role of the BMS and how to read the state of charge.

3.2 VNominal voltage per cell
3.60 VEnd of charge (max 3.65 V)
2.5 VAbsolute minimum
0 – 45 °CCharging temperature
The chemistry

Why a LiFePO4 is not charged like a LiPo

LiFePO4 cells have a nominal voltage of 3.2 V, against the 3.6–3.7 V of Li-ion and LiPo. Four cells in series make 12.8 V: that is why they are the natural replacement for 12 V lead-acid batteries. The iron phosphate cathode is chemically stable, does not release oxygen when abused and lasts thousands of cycles; the price is a lower energy density.

The difference that matters for charging is another one: the voltage curve is almost flat. Between 20 % and 90 % charge a cell sits between 3.2 and 3.35 V. That changes three things: the end-of-charge voltage must be respected to the hundredth, the state of charge is hard to read from the voltage, and balancing can only happen at the top.

4.2 V 3.7 V 3.3 V 3.0 V 2.5 V Li-ion / LiPo LiFePO4 — almost flat from 90 % to 20 %: less than 0.15 V apart 100 % 50 % 0 %
Typical cell voltage during discharge. On a Li-ion the voltage tells you how much energy is left; on a LiFePO4 it tells you almost nothing until the last few per cent. That is why a voltmeter is not enough to know how charged a LiFePO4 is.
The charge profile

Constant current, then constant voltage, then stop

LiFePO4 batteries are charged with the CC/CV profile. In the first stage (CC) the charger delivers a constant current and the voltage rises on its own. When it reaches 3.60 V per cell the charger switches to the CV stage: it holds the voltage and lets the current fall. Charging is complete when the current drops to about C/20 — 0.5 A for a 10 Ah battery.

After that, the charger should switch off. Unlike lead-acid, a LiFePO4 needs no maintenance charge: keeping it at 100 % all the time does it no good and ages it. If the charger has to stay connected, set the float low, at about 3.375 V per cell (13.5 V for a 4S).

3.60 V 3.30 V 2.8 V 0.5C C/20 CC — constant current CV — constant voltage cell voltage charge current end of charge: current ≤ C/20 → stop time →
The CC stage takes the battery to about 90–95 %; the CV stage adds the last part and gives the BMS time to balance the cells. On a LiFePO4 the voltage only jumps at the very end: until then it stays on the plateau around 3.3–3.4 V.
Bench rule 3.65 V per cell is a limit, not a target. Charging to 3.60 V (or even 3.50–3.55 V) costs very little capacity and extends cell life; going above 3.65 V gives you no extra energy and trips the BMS.
Voltages

The right voltages for every configuration

A LiFePO4 battery is made of cells in series: 4S means four cells, that is 12.8 V nominal. Multiply the single-cell values by the number of cells and you have the voltages to set on the charger.

ConfigurationNominalEnd of charge (CV)Float, if neededDischarge minimum
1S — one cell3.2 V3.60 – 3.65 V3.375 V2.5 V
2S6.4 V7.2 – 7.3 V6.75 V5.0 V
4S — "12 V"12.8 V14.4 – 14.6 V13.5 V10.0 V
8S — "24 V"25.6 V28.8 – 29.2 V27.0 V20.0 V
16S — "48 V"51.2 V57.6 – 58.4 V54.0 V40.0 V

The discharge minimum is a protection limit, not a working point: below 2.8–3.0 V per cell less than 10 % of the capacity is left. For everyday use, stop there and leave 2.5 V as the BMS's last line of defence.

Current and times

How much current, and how long it takes

Charge current is expressed in multiples of the capacity, C: for a 10 Ah battery, 1C is 10 A and 0.5C is 5 A. The standard value for LiFePO4 is 0.5C; many cells accept 1C, some more. The real limit is in two places: the cell datasheet and the BMS, which often has a lower maximum charge current than discharge current.

Current10 Ah battery100 Ah batteryTime from empty, approx.
0.2C2 A20 A5 – 5.5 h
0.5C5 A50 A2 – 2.5 h
1C10 A100 A1 – 1.5 h

The times include the final CV stage, which weighs more at high currents. A slow charge does no harm and leaves more time for balancing; a 1C charge is fine if the cells and the BMS allow it and the battery is not already warm.

BMS and balancing

The BMS protects, balancing happens at the top

Every LiFePO4 battery with several cells in series needs a BMS (battery management system). The BMS watches the voltage of each cell and opens the circuit if one goes above about 3.65–3.75 V while charging or below about 2.5 V while discharging; it usually also protects against overcurrent, short circuit and — in the better models — charging below freezing.

The BMS is not a charger, though: it is an emergency switch. If it is the BMS that stops the charge, either the voltage you set is too high or the cells are out of balance.

Why balancing only works when the battery is nearly full

To balance, the BMS has to know which cell holds more charge than the others. On the flat plateau all the cells show the same voltage even when they hold different amounts of energy; the differences only show above about 3.4 V. That is why passive balancing works in the final CV stage. If you always charge to 80 % and never to 100 %, do a full charge now and then and leave the battery on the charger an extra hour: that is when the cells line up again.

New or self-built pack Before first use, bring all the cells to the same voltage: in parallel, or by charging them one by one to 3.60 V. A pack that starts out of balance trips the BMS during charging when the highest cell reaches the limit, and the others are left behind.
Which charger

The right charger, and the ones to avoid

The rule is simple: the charger must end the charge at 3.60–3.65 V per cell and have no higher-voltage stages. Here is how the most common types behave.

ChargerSuitable?What to check
Dedicated LiFePO4YesFinal voltage equal to number of cells × 3.60–3.65 V
Hobby balance chargerYes, with the LiFe programmeSelect LiFe, not LiPo/LiIon: the LiPo programme goes to 4.2 V per cell
Lead-acid with a "Lithium" profileYesAbsorption 14.2–14.6 V, no equalisation, temperature compensation off
Generic lead-acidBetter notEqualisation and desulphation stages exceed 15 V and trip the BMS
MPPT/PWM solar controllerYes, if configurableAbsorption 14.2–14.4 V, float 13.4–13.5 V or off, no equalisation
Li-ion / LiPo at 4.2 VNoOvercharges the cells: 4.2 V is well above the 3.65 V limit
Bench power supplyYes, with careCurrent limit set, exact voltage, and disconnect it when charging ends

Charging from an alternator or a DC-DC charger

In campervans and boats the alternator sees a LiFePO4 as a huge load, because its internal resistance is low: it can overheat. Use a DC-DC charger with a LiFePO4 profile, which limits the current and applies the right voltage.

Temperature and storage

Never below freezing, and half full when resting

A LiFePO4 is charged between 0 and 45 °C. Below freezing, lithium plates onto the surface of the graphite anode instead of entering it: the lost capacity never comes back. Discharging is possible below freezing, with less capacity available. If the battery works in the cold you need a BMS with low-temperature charge cut-off or a heated battery.

For storage leave it at around 50 %, about 3.30 V per cell at rest, disconnected from loads and somewhere cool. Self-discharge is low, but the BMS and any displays draw a little: check the voltage every two or three months.

SituationRange
Charging0 – 45 °C
Discharging−20 – 60 °C (reduced capacity in the cold)
Storageabout 50 %, 3.30 V per cell, 10 – 25 °C
State of charge

Reading the voltage, knowing how little it says

With a LiFePO4 the voltage is only reliable at the extremes. Measure it at rest, after at least an hour with no charge or discharge: while charging it reads higher, under load lower. To know how much energy is really left you need a shunt monitor that counts the amp-hours in and out.

Resting voltage per cell4S batteryApproximate state of charge
3.40 V13.6 V100 %
3.35 V13.4 V≈ 95 %
3.32 V13.3 V≈ 90 %
3.30 V13.2 V≈ 70 %
3.27 V13.1 V≈ 40 %
3.25 V13.0 V≈ 30 %
3.20 V12.8 V≈ 15 %
3.00 V12.0 V≈ 10 %
2.50 V10.0 V0 %

Measuring it with Arduino

To keep an eye on a 4S with an Arduino you need a divider: the 14.6 V of a full battery has to be brought below the 5 V of the analogue input. With 30 kΩ and 10 kΩ the voltage is divided by 4 — 14.6 V becomes 3.65 V — and the divider draws less than half a milliamp.

LiFePO4 4S · 14.6 V max 30 kΩ 10 kΩ Arduino A0 GND ≤ 3.65 V
30 kΩ / 10 kΩ divider: A0 sees a quarter of the battery voltage. The battery and Arduino grounds must be joined.
lifepo4_monitor.ino4S battery
// Reads a 4S LiFePO4 on A0 through a 30k / 10k divider (ratio 4).
const float VREF    = 5.00;   // measure your 5 V with a multimeter
const float DIVIDER = 4.00;   // (30k + 10k) / 10k
const int   CELLS   = 4;

// Resting voltage per cell -> state of charge (approximate).
const float V[]   = { 2.50, 3.00, 3.20, 3.25, 3.27, 3.30, 3.32, 3.35, 3.40 };
const int   SOC[] = {    0,   10,   15,   30,   40,   70,   90,   95,  100 };

int socFromCell(float v) {
  if (v <= V[0]) return 0;
  for (int i = 1; i < 9; i++)
    if (v < V[i])                       // linear interpolation
      return SOC[i-1] + (v - V[i-1]) * (SOC[i] - SOC[i-1]) / (V[i] - V[i-1]);
  return 100;
}

void setup() { Serial.begin(115200); }

void loop() {
  long sum = 0;
  for (int i = 0; i < 32; i++) sum += analogRead(A0);   // average
  float pack = sum / 32.0 * VREF / 1023.0 * DIVIDER;
  float cell = pack / CELLS;

  Serial.print(pack, 2); Serial.print(" V  cell ");
  Serial.print(cell, 3); Serial.print(" V  ~");
  Serial.print(socFromCell(cell)); Serial.println(" %");
  if (cell < 3.00) Serial.println("WARNING: recharge the battery");
  delay(2000);
}

The percentage is only meaningful at rest, and only as accurate as the measurement: a 20 mV error on the cell moves the estimate by tens of points on the plateau. Calibrate VREF with a multimeter and use 1 % resistors.

Troubleshooting

When something is not right

SymptomTypical causeRemedy
Charging stops before 100 %The BMS cuts off: one cell reaches 3.65 V before the othersSlow, long CV charge to balance; if it persists, balance the cells by hand
The charger will not startBMS in protection after a deep discharge, 0 V at the terminalsCharger with a lithium "wake-up" function, or a short low-current charge
The battery will not charge in winterBMS with charge cut-off below 0 °CBring the battery above freezing before charging
The charger never finishesLead-acid profile with a high maintenance voltageLiFePO4 profile, or float at 13.5 V for a 4S
The BMS cuts off at the end of charge with a lead-acid chargerEqualisation stage above 15 VDisable equalisation or change charger
The voltage drops right after chargingNormal: from 3.60 V on charge it settles to about 3.35–3.40 V at restNothing: measure after an hour at rest
Much reduced capacityUnbalanced cells, charged in the cold or very deep cyclesFull charge with balancing; check cell by cell
FAQ

Frequently asked questions about charging LiFePO4

What voltage do you charge a LiFePO4 battery to?

3.60 V per cell, with an absolute maximum of 3.65 V. For a 12.8 V battery (4 cells in series) that means 14.4–14.6 V; for a 25.6 V battery (8S) 28.8–29.2 V. Charging is CC/CV: constant current up to the final voltage, then constant voltage until the current drops to about C/20.

Can I charge a LiFePO4 with a lead-acid charger?

Only if it has a LiFePO4 profile, or if the absorption voltage is 14.2–14.6 V with no equalisation or desulphation stage. Equalisation modes go above 15 V and trip the BMS or damage the cells; temperature compensation must be switched off.

Can I use a Li-ion or LiPo charger?

Not if it works at 4.2 V per cell: it would overcharge the LiFePO4. A hobby balance charger is fine only if it has a LiFe programme, which ends the charge at 3.6 V per cell.

What current should I charge a LiFePO4 at?

The typical value is 0.5C, half the capacity in amps: 5 A for a 10 Ah battery. Many cells accept up to 1C, but the real limit is in the datasheet and in the BMS, which often has a lower maximum charge current than discharge current.

Can you charge a LiFePO4 below freezing?

No. Below 0 °C lithium plates onto the anode instead of entering the graphite, and the cell loses capacity permanently. Charge between 0 and 45 °C; discharging below freezing is possible.

How do you store an unused LiFePO4 battery?

At around 50 % charge, about 3.30 V per cell at rest, disconnected from loads and somewhere cool. Self-discharge is low, but the BMS draws a little: check the voltage every two or three months and never let it fall below 2.5 V per cell.